Physical Specifications

Command Module: 30.48 x 45.72 x 25.40 cm 12" x 18" x 10"

Reaction Module: 45.7 x 33.0 x 60.9 cm 18" x 13" x 24" 

Height of Storage Module/Wheels Attached: 69.9 cm 27.5"H 

Total Height: 116.8 cm 46" 

 

Power Requirements: 

Command Module: 120V, 60Hz, 150VA Reaction Module: 1200VA Weight: Command Module: 9.1 kg 20 lbs. Reaction Module: 46.7 kg 103 lbs. Shipping Weight: approx.181.4 kg 400 lbs 

Agency Approvals: Designed to meet IEC 1010, CSA, and UL.

 

 

 

 

  

Features

 

  • The Hypercenter XP is a computer-controlled, fluid transfer tissue processor with automated fixation, dehydration, cleaning and paraffin infiltration of tissue specimens.

 

  • Fully Enclosed System 

 

  • The Reagent Storage Module does not allow reagent fumes to vent into laboratory atmosphere when the Hypercenter is in operation.

 

  • Flexible air bag which maximizes the system’s air capacity. 

 

  • Emergency activated carbon filter is utilized as an additional safety feature only if there is excess pressure.

 

  • Optimized Design 

 

  • Organized capacity of 180 cassettes.

 

  • Can be configured as either a floor model or bench-top model. 

 

  • One Command Module can control up to 5 reaction and storage modules for processing capacity of up to 900 cassettes per load.

 

  • Save as many as 9 customized programs

 

  • Unit comes with default processing parameters available at each step of heat, vacuum, immersion time and extended drain time.

 

  • A time-of-day clock continuously displays and is used by the instrument to calculate and set continuous, real-time processing log. 

 

  • Software is programmed to accommodate year 2000 changes.

 

  • Multilingual-Continuous on-screen prompts display in user choice of English, Spanish, French, Italian, German or Swedish. 

 

  • Vacuum and positive pressure move reagents to and from the sealed specimen chamber through a single, rotary valve located in the reagent storage module.

 

  • Second blowout of reagent at every step. 

 

  • Two independent paraffin baths completely infiltrate the specimen with paraffin.

 

  • Flush (purge) cycle automatically cleans the unit with heated xylene (or substitute) and then alcohol.

 

  • Glass specimen chamber lid allows the user to see the specimens during processing without opening the sealed lid.

 